HPD High Pressure Dryers
Air flow rate up to 1200m3/h
Â
OMI HP refrigeration dryers provide dry compressed air for applications up to 45 bar. HP series guarantees a +3°C dew point and maximum reliability thanks to a new heat exchanger design more compact and efficient than the previous models. The range of HP dryers consists of 10 models that allows to uniformly cover flow rates up to 1200 m³/h.Â
All models are equipped with a safety valve that activates in case of direct contamination between refrigerant gas and compressed air.Â
AVAILABLE OPTIONS:Â
-
ED 480-1200 HP are available with 230/1/60 power supply
Â
Â
Share
Â
The HP Dryers are especially useful for various applications requiring high pressure air flow such as blow molding for the production of PET containers and bottling, water jet cuts, aeronautical valves and other special applications.
Our HP Dryers feature a 3-in-1 heat exchanger - Include evaporator, separator, pre-cooler/heater.
Air compressor compresses hot and moist air to the pre-cooler of a 3-in-1 heat exchanger, then the hot & moist air exchanges heat with treated cold air.
This chilled moist air enters the evaporator, lower down temperature and condensate water out by evaporation. After, the air moves to the separator, with centrifugal force and gravity, the condensate water can be separated from air.
Finally, the cool & dry air goes back to preheater to be heated to the working temperature.
Evaporator:
- Condense out moisture from air through our high efficiency heat exchanger.
- High efficiency, low dew point, and low pressure drop.
Separator:
- Centrifugal force and gravity separate moistures from air.
- No mesh designed, clogging free, easy to maintain.
Pre-cooler/heater:
- Save energy by exchanging heat from inlet and outlet air temperature.
- Outlet air can be used directly. It is preheated to the working temperature.
Â
Â
Â
Model | Code | Connections | Flow rate (m³/min) | Flow rate (l/min) | Flow rate (CFM) | Nominal power consumption (KW) | ISO8573-1:2010 Classification | Datasheets |
---|---|---|---|---|---|---|---|---|
ED 88 HP | 08N.0088BGO | 1/2" | 88 | 1.470 | 52 | 0.17 | Water content: Class 4, Dewpoint: 3°C / 37,4 °F | Download |
ED 108 HP | 08N.0108BGO | 1/2" | 108 | 1.800 | 64 | 0.17 | Water content: Class 4, Dewpoint: 3°C / 37,4 °F | Download |
ED 180 HP | 08N.0180BGO | 1/2" | 180 | 3000 | 106 | 0.41 | Water content: Class 4, Dewpoint: 3°C / 37,4 °F | Download |
ED 225 HP | 08N.0225BGO | 1/2" | 225 | 3750 | 132 | 0.41 | Water content: Class 4, Dewpoint: 3°C / 37,4 °F | Download |
ED 270 HP | 08N.0270BGO | 1/2" | 270 | 4500 | 159 | 0.55 | Water content: Class 4, Dewpoint: 3°C / 37,4 °F | Download |
ED 360 HP | 08N.0360BGO | 1/2" | 360 | 6000 | 212 | 0.81 | Water content: Class 4, Dewpoint: 3°C / 37,4 °F | Download |
ED 480 HP | 08N.0480BGO | 1" 1/4 | 480 | 8000 | 283 | 0.9 | Water content: Class 4, Dewpoint: 3°C / 37,4 °F | Download |
ED 660 HP | 08N.0660BGO | 1" 1/4 | 660 | 11000 | 389 | 1.23 | Water content: Class 4, Dewpoint: 3°C / 37,4 °F | Download |
ED 990 HP | 08N.0990BGO | 1" 1/4 | 990 | 16500 | 583 | 1.23 | Water content: Class 4, Dewpoint: 3°C / 37,4 °F | Download |
ED 1200 HP | 08N.1200BGO | 1" 1/4 | 1200 | 20000 | 706 | 1.43 | Water content: Class 4, Dewpoint: 3°C / 37,4 °F | Download |
Â
Â
Features
Â
The HP Dryers are especially useful for various applications requiring high pressure air flow such as blow molding for the production of PET containers and bottling, water jet cuts, aeronautical valves and other special applications.
Our HP Dryers feature a 3-in-1 heat exchanger - Include evaporator, separator, pre-cooler/heater.
Air compressor compresses hot and moist air to the pre-cooler of a 3-in-1 heat exchanger, then the hot & moist air exchanges heat with treated cold air.
This chilled moist air enters the evaporator, lower down temperature and condensate water out by evaporation. After, the air moves to the separator, with centrifugal force and gravity, the condensate water can be separated from air.
Finally, the cool & dry air goes back to preheater to be heated to the working temperature.
Evaporator:
- Condense out moisture from air through our high efficiency heat exchanger.
- High efficiency, low dew point, and low pressure drop.
Separator:
- Centrifugal force and gravity separate moistures from air.
- No mesh designed, clogging free, easy to maintain.
Pre-cooler/heater:
- Save energy by exchanging heat from inlet and outlet air temperature.
- Outlet air can be used directly. It is preheated to the working temperature.
Â
Â
Technical specifications
Â
Model | Code | Connections | Flow rate (m³/min) | Flow rate (l/min) | Flow rate (CFM) | Nominal power consumption (KW) | ISO8573-1:2010 Classification | Datasheets |
---|---|---|---|---|---|---|---|---|
ED 88 HP | 08N.0088BGO | 1/2" | 88 | 1.470 | 52 | 0.17 | Water content: Class 4, Dewpoint: 3°C / 37,4 °F | Download |
ED 108 HP | 08N.0108BGO | 1/2" | 108 | 1.800 | 64 | 0.17 | Water content: Class 4, Dewpoint: 3°C / 37,4 °F | Download |
ED 180 HP | 08N.0180BGO | 1/2" | 180 | 3000 | 106 | 0.41 | Water content: Class 4, Dewpoint: 3°C / 37,4 °F | Download |
ED 225 HP | 08N.0225BGO | 1/2" | 225 | 3750 | 132 | 0.41 | Water content: Class 4, Dewpoint: 3°C / 37,4 °F | Download |
ED 270 HP | 08N.0270BGO | 1/2" | 270 | 4500 | 159 | 0.55 | Water content: Class 4, Dewpoint: 3°C / 37,4 °F | Download |
ED 360 HP | 08N.0360BGO | 1/2" | 360 | 6000 | 212 | 0.81 | Water content: Class 4, Dewpoint: 3°C / 37,4 °F | Download |
ED 480 HP | 08N.0480BGO | 1" 1/4 | 480 | 8000 | 283 | 0.9 | Water content: Class 4, Dewpoint: 3°C / 37,4 °F | Download |
ED 660 HP | 08N.0660BGO | 1" 1/4 | 660 | 11000 | 389 | 1.23 | Water content: Class 4, Dewpoint: 3°C / 37,4 °F | Download |
ED 990 HP | 08N.0990BGO | 1" 1/4 | 990 | 16500 | 583 | 1.23 | Water content: Class 4, Dewpoint: 3°C / 37,4 °F | Download |
ED 1200 HP | 08N.1200BGO | 1" 1/4 | 1200 | 20000 | 706 | 1.43 | Water content: Class 4, Dewpoint: 3°C / 37,4 °F | Download |
Â
Â